Golden Ricky

Home  ›  HPL  ›  Fire-Rated Board
A-grade non-combustible · Fire-rated

Fire-Rated HPL — A-Grade Non-Combustible Boards

Golden Ricky fire-rated HPL is an A-grade non-combustible board engineered for facades, high-rise cladding and public buildings where fire safety is non-negotiable. It combines certified Class A / B1 fire performance with the full decorative range of high pressure laminate.

Fire-rated HPL A-grade non-combustible board
Class A / B1Certified fire rating
Non-combustibleA-grade mineral core
EN 13501 · GB 8624Tested to fire standards
Indoor & outdoorInterior & exterior grades
Overview

What is fire-rated HPL?

Fire-rated HPL is a high pressure laminate engineered to resist ignition and limit the spread of flame. Our A-grade non-combustible board carries a Class A / B1 fire rating, which means it adds little or no fuel to a fire and releases minimal smoke. Unlike a standard decorative HPL sheet, the core is formulated with non-combustible mineral content so the panel meets strict fire-safety requirements.

This makes the board the specified choice for building facades, ventilated cladding, stairwells, corridors, lifts, transport interiors and other areas where building codes demand certified fire performance. Available in both interior and weatherproof exterior grades, the board still offers the full decorative range of our high pressure laminate — over 1000 designs and finishes — so safety never comes at the cost of looks. Fire test certificates are available on request.

Why choose it

Benefits of fire-rated HPL

Certified fire safety with the durability and design freedom of high pressure laminate.

01

Certified fire performance

Class A / B1, tested to EN 13501-1 and GB 8624 — documentation supplied on request.

02

Non-combustible core

A mineral-loaded A-grade core that contributes minimal fuel to a fire.

03

Low smoke & droplets

Limits smoke generation and flaming droplets to help protect escape routes.

04

Interior & exterior grades

Weatherproof exterior board for facades; interior board for walls and ceilings.

05

Durable & hygienic

Scratch-, impact- and moisture-resistant, easy to clean and long-lasting.

06

1000+ designs

Woodgrains, stones, solids and metallics in matt, gloss and textured finishes.

Designs & colours

Non-combustible board designs & finishes

Choose from over a thousand designs and colours across our surface series.

Woodgrain HPL finishWoodgrain
Stone HPL finishStone
Solid colour HPL finishSolid
Marble HPL finishMarble
Metallic HPL finishMetallic
Textured HPL finishTextured
Browse all 1000+ designs
Specifications

Non-combustible board specifications

Our non-combustible boards are manufactured to international standards including EN 438 and ISO 4586, and fire-tested to EN 13501-1 and GB 8624. Want to confirm the rating for your project? Contact our team for fire test certificates and full technical data. You can also read our guide on whether HPL is fire-safe.

ProductFire-rated HPL / A-grade non-combustible board
Fire ratingA-grade non-combustible (Class A / B1)
Fire standardsEN 13501-1, GB 8624
Thickness0.8 – 25 mm (sheet & compact grades)
Standard size4 × 8 ft (1220 × 2440 mm)
Other sizes (mm)1220 × 3050, 1310 × 3050, 1525 × 3050, 1525 × 3660
GradesInterior & weatherproof exterior
StandardsEN 438, ISO 4586
CustomisationCut-to-size, OEM & private label
FAQ

Fire-rated board FAQs

What is fire-rated HPL?
Fire-rated HPL is a high pressure laminate engineered to resist ignition and limit flame spread. Our A-grade non-combustible board carries a Class A / B1 fire rating and is used where building codes require certified fire performance.
What fire rating does the board have?
It is an A-grade non-combustible board rated Class A / B1, tested to EN 13501-1 and GB 8624. We can provide the relevant fire test certificates for your project.
Is standard HPL fire-resistant?
Standard decorative laminate is combustible. For projects with fire-safety requirements you need a dedicated fire-rated HPL with a non-combustible core, like this A-grade board. See our guide on whether HPL is fire-safe for more.
Where is it used?
Typical uses include building facades, ventilated cladding, stairwells, corridors, lift interiors, transport vehicles and the interiors of hospitals, schools, hotels and transport hubs.
Can it be used on exterior facades?
Yes. Our weatherproof exterior grade combines non-combustible fire performance with UV, rain and temperature resistance, making it suitable for high-rise facades and ventilated cladding.
What sizes and thicknesses are available?
Fire-rated HPL is available as both bonded sheets and self-supporting compact boards, from about 0.8 to 25 mm, in our standard 4 × 8 ft size and larger formats, with cut-to-size on request.
Do you provide fire test certificates?
Yes. We supply fire test certificates and full technical data on request — send your project details via our contact options or WhatsApp.

Request samples & fire test data

Tell us your project and fire-rating requirement — we'll send samples and certificates fast.

Chat on WhatsApp